D86 debugger package   V4.05             January 14, 2000

The entire package is Copyright 2000 Eric Isaacson. All
rights reserved.

PLEASE read Chapter 1 for legal terms and conditions, how to
register for the package, and an overview of the debugger.

The D86 package consists of the two programs D86.COM, A86.COM, a
source file HEXOUT.8 used by the demonstration in Chapter 2, and
this manual D86MANU.TXT.


TABLE OF CONTENTS


1 INTRODUCTION AND LEGAL TERMS   3

Introduction                     3

2 D86 DEMONSTRATION   6

3 REQUIREMENTS AND OPERATION           9

System Requirements for D86            9
Invoking D86                           9
Finding the Program File               9
Finding the Symbols File               9
BIOS Switching                        10
The D86 Environment Variable          10
Two-Screen Debugging with +V          10
The D86 Screen Display                10
D86 Commands                          11
Immediate Assembly Language Commands  11
Entering Instructions Into Memory     11
Entering Data into 8086 Memory        12
Adding Symbols to a Program           12

4 D86 CONTROL KEYS                            13

Display Control Keys                          13
Instruction Pointer Positioning Control Keys  13
Program Execution Control Keys                14
Special Action Control Keys                   15

5 COMMAND LANGUAGE                     16

General Operands to Debugger Commands  16
Format of Debugger Command Examples    16
The Debugger Command Set               16

6 MEMORY DISPLAY OPTIONS              21

Memory Display Windows                21
Single-Line Memory Windows            21
Erasing Memory Display Lines          21
Continuation Lines                    22
Mixed Format Specification            22
Numbers in a Format Specification     22
Spacing Between Memory Display Units  22
                                                               2

Special-Action Format Specifiers      23
The Data Memory Window                25

7 FLOATING POINT DEBUGGING                26

The Floating Point Display Window         26
Exotic Flavors of Floating Point Numbers  27

8 COMMONLY ASKED QUESTIONS  29

Setting Registers           29
Modifying Memory            29
Debugging ROM               29

9 RELEASE HISTORY AND FUTURE PLANS  30

Release History of D86              30
Future Plans                        30
                                                               3


CHAPTER 1   INTRODUCTION AND LEGAL TERMS


Introduction


D86 is a screen-oriented assembly language debugger for the
IBM-PC, compatibles, and most not-so-compatibles (Wang-PC, TI-PC,
Tandy 2000, Sanyo 55x, Zenith Z-100, and DEC Rainbow).  D86 is
the finest debugger available, at any price under any conditions,
for the following:

1. Learning 8086 assembly language.

2. Exploring the machine state of your computer (memory
   structure, registers, etc.)

3. Doing assembly language program development using my A86
   assembler.

4. Doing any kind of debugging involving the floating point
   instruction set.


In contrast to software firms who attempt to restrict the
distribution of their software through protection schemes, I
encourage free distribution, and trust that those who use my
products will pay for them.  Please keep in mind the fundamental
good spirit of free-distribution software as you endure the
following barrage of legalities.  Then evaluate the outstanding
value that the D86 package offers you.  I assure you that you
will not be disappointed.


Legal Terms and Conditions

This package is provided to you under the following conditions:

1. You may copy this entire package, and give it to anyone who
   accepts these terms.  The copies you distribute must be
   complete and unmodified.  You do not have to be registered to
   distribute this package.

2. Even if you have not yet obtained full execution rights, you
   may execute the programs in this package, in order to evaluate
   them.  If you decide that D86 is of use to you, you must
   become a registered user.  There are two levels of
   registration: the basic D86-only registration is $50 ($52 if
   you are outside of North America).  The extended package,
   including D86, the associated A86 assembler, and the 32-bit
   programs A386 and D386, is $80 ($82 outside of North America).
   If you wish the latest printed copy of this manual, add $10
   ($15 outside of North America).  Send payment to:

      Eric Isaacson
      416 E. University Ave.
      Bloomington, IN 47401-4739

   For your convenience, I accept Visa, MasterCard and American
   Express, by telephone or mail.  My voice number is
   1-812-339-1811.  My fax number is 1-812-335-1611.

   For the convenience of users in Great Britain, I have
   authorized the firm Atlantic Coast Plc to collect
   registrations for me.  We'll try to keep the prices about the
   same whether you register through me or through them; it's
   your choice.  Their address is Station Road, Colyton, Devon
   EX13 6HA, telephone 01297 552222.

   Your registration includes the latest diskette (3.5 inch) that
   also includes the INSTALLD and MAPD86 tools available to
   registered users only.  You may order further updates for $10
   US, or $12 US if you are overseas.  Once you register for this
   package, you are registered for all future versions -- you
   have permanent rights to execute D86 on one computer.  As long
   as I'm in business, you can get the latest version for just
   the update fee.

   Indiana residents need to add sales tax.  At the current rate
   of 5%, the prices for Indiana residents are $52.50 for the
   D86-only package, $63 D86-only with manual, $84 extended
   package, $94.50 extended package with manual, $21 update and
   manual if already registered.

   Educational institutions and training facilities MUST be
   registered in order to use D86 in courses.  Contact me for
   special terms.

   Companies and government agencies MUST be registered in order
   to use D86 for their work.  Again, contact me for pricing if
   you wish to register D86 on more than one computer.

3. You may not sell this package to anyone.  If you distribute
   this package on a diskette, any fees you collect must be
   specified as materials/handling, and may not exceed $10 for
   the diskette.

4. You are completely responsible for determining the fitness or
   usability of this package.  I will not be liable for any
   damages, of any kind, arising from any failure of any programs
                                                               4

   in this package to perform as expected.


Registration Benefits

Thank you for enduring the legalities.  They are there to protect
me, and also to convince you that this is my business, from which
I expect to make a living.  I'll now return to a softer sell, to
try to make you want to register for my products.

There is a certain amount of ambiguity about when you're still
evaluating D86, and when you're really using D86 and should
register for it.  Some cases are clear (e.g., you're a school
using D86 to teach a course); but many are not.  In practical
reality, it up to you to decide: you are "on your honor". Also in
practical reality, most users who ought to register haven't, yet.
For most, it's not dishonesty but merely procrastination.  So I
have provided some incentives, to prod you into registering.

One incentive is the printed manual, which only registered users
can purchase.  I haven't left anything out of the disk version of
the manual, but the printed version is formatted and bound much
more nicely than if you print it yourself.

Another incentive, included if you register both A86 and D86, is
the A386/D386 package, for 32-bit programming.  At this writing,
A386 covers all instructions though the Pentium II, including
MMX, AMD 3DNow, and the not-yet-released KNI instruction set.
A386 also allows coding for USE32 and FLAT mode segments.

Another incentive is a file REG_ONLY.ZIP containing extra tools
that enhance D86's usefulness.  If you program in languages other
than A86, and produce the program with a linker, you can use the
tool MAPD86 to convert a link MAP listing into a SYM file
readable by D86, so you can do symbolic debugging. If you have a
386-based machine, you can add the D command to D86, allowing you
to set memory breakpoints.

Finally, there are the intangible incentives.  You know you've
done the right thing.  You're letting me know that you appreciate
what I've done.  You're letting the world know that quality
software can succeed when distributed as shareware.


Overview of D86

D86 is a screen-oriented program that allows you to troubleshoot
faulty computer programs written for the IBM-PC and all
compatibles, Wang-PC, TI-PC, Tandy 2000, DEC Rainbow, and Sanyo
computer.  It "freezes" the state of your program, and allows you
to investigate the values of registers, flags, and memory.  You
can monitor your program's execution by stepping it one
instruction or procedure at a time; or you can start your program
running, telling D86 to stop it when it reaches certain
locations.  D86 recognizes the symbol-table output of the A86
assembler, creating a symbolic disassembly of your A86 program,
and allowing you to refer to locations and variables by name.

The primary design criterion for D86 is ease of use.  This is
reflected in the most notable features of D86:

* You don't need to ask D86 what the values of registers and
  flags are.  They are there, automatically, at a fixed location
  on the screen.

* You don't need to ask D86 where in your program you are
  stopped.  A disassembly is always generated, at another fixed
  location on the screen. The disassembly gives a hefty chunk of
  your program, not just the single instruction you are at.  A
  cursor next to the disassembly marks the current location.  The
  disassembly chunk remains fixed as you step though it, allowing
  you to follow the flow of the program much more easily.  If you
  wrote the program using A86, the disassembly is symbolic,
  giving instruction operands by name, and labelling disassembly
  locations when possible.

* You don't need to ask D86 what is on the machine stack. A
  display of the top elements of the stack is always generated,
  at yet another fixed location on the screen.

* You can set up windows into memory, displaying memory contents
  in a variety of types.  The types can even be mixed, to display
  complicated structures. The windows will stay at the same
  location until you turn them off, allowing you to watch what
  your program is doing to those memory locations.

* If you have an 8087 or 287 floating-point chip, D86 will
  generate complete window of the 87 state.  The values of the
  stack elements are in a readable decimal format, with
  suppression of unneccessary zeroes, and scientific notation
  only if necessary.

* You can, at any time, enable a help-window, to guide you
                                                               5

  through debugger commands.  You will be astounded by the
  sophistication of this help-facility, especially since other
  debuggers offer no on-line help whatsoever.

* All of the above-mentioned windows, except for the last two,
  exist on the screen at the same time.  You don't have to switch
  between them.

* You can single-step your program with single keystrokes, rather
  than sequences of arcane commands.  There are several flavors
  of single-step keys, clustered together on the function-keypad.
  This, combined with the automatic nature of the display, allows
  you to single-step very quickly.  You feel like you are
  actually watching your program run.

* Much of D86's command language is simply the A86 assembly
  language itself. You can type in any A86 instruction, to be
  executed immediately.  You use this to set registers and
  variables, perform arithmetic, jump to another location, etc.
  The immediate-execution feature makes D86 the most effective
  tool available for teaching 86 architecture: the student can
  watch the effects of instructions on registers, flags, and
  memory.

* You can patch programs in memory, using the full power of the
  A86 assembly language.


How to Contact Me

I have no plans to move from my present location at least through
the millennium.  So you can write to:

    Eric Isaacson Software
    416 East University Ave.
    Bloomington, IN 47401-4739

or call (812)339-1811.

Sorry, I can't guarantee to return everybody's long distance
calls.  If you'd like to be SURE I'll get back to you, please
invite me to call you back collect, or tell me to charge the cost
of the call to your credit card.

I also have a section on Compuserve: just type GO ZIPKEY to any !
prompt.  (ZIPKEY is the name of my other product line, a pop-up
zipcode directory.)  My Internet address is eric@eji.com .

PLEASE contact me if you find bugs in my programs; I'll fix them!
I accept bug reports from anyone, registered or non-registered,
no questions asked.  It's very frustrating to hear about people
telling each other about bugs, and not telling me.  I still await
Greg Wettstein's bug list.


This manual also covers the D386 debugger. D386 is the 32-bit
version of the debugger, allowing you to use the full A386
instruction set for immediate and patched commands, and showing
you the 32-bit general register set. D386 is a DOS-based,
real-mode debugger only: it cannot step into Protected Mode, and
it cannot load Protected Mode programs (e.g., Windows programs).
                                                               6


CHAPTER 2   D86 DEMONSTRATION

To demonstrate some of the powers of D86, let's walk through a
D86 session.

1. Make sure your current directory contains all the files
   A86.COM, D86.COM, and HEXOUT.8.

2. Assemble the HEXOUT program by typing the command A86
   HEXOUT.8.  The A86 assembler will create the files HEXOUT.COM
   and HEXOUT.SYM.  Look over the listing of the program, to get
   acquainted with what it does.

3. Type the command D86 HEXOUT 41 42 5A followed by the Enter
   key. Everything following the "D86 " in the line you just
   typed is what you would have typed if you had invoked HEXOUT
   without the debugger-- 41 42 5A are the hex codes that HEXOUT
   will turn into ABZ and send to the console. When the debugger
   takes control, the screen should blank; and the D86 debugger
   screen should appear.  The blinking cursor should be at the
   bottom left.  A sign-on message should appear at the upper
   right.  A disassembly of the HEXOUT program should be in the
   upper left. The label HEXOUT should appear on the first line,
   followed on the second line by the address 0100 and the
   instruction MOV SI,TAIL_BUFF.  To the left of the address
   should be a reverse video hash sign.

4. Notice the display of register values in the lower left
   corner. The values are all 4-digit hexadecimal.  At the top of
   the second column of registers is a sequence of lower case
   letters. This is the flags display.  Each small letter stands
   for a flag whose value is currently TRUE.  The flags settings
   are those that were handed to D86 by the operating system
   starting the program; for MSDOS V3.1, the settings are "i z
   e".  That display indicates that the interrupt flag "i", the
   zero flag "z", and the parity-even flag "e" are all TRUE; the
   other flags are FALSE. To the right of the registers are six
   lines labelled 1: through 6:.  These are the memory window
   lines. Since you haven't specified any memory windows yet,
   they contain nothing but their numbers.  Below the memory
   window lines is a line labelled 0:.  This is the stack display
   line. The number 0: gives the number of words on the stack,
   currently zero because nothing has been pushed onto the stack.

5. Observe that the sign-on message tells you to press Alt-F10
   for help.  Do so (that is, hold down the Alt key while
   pressing the F10 key).  You are now in help mode, where you
   will remain until you press Alt-F10 again.  D86 will keep
   changing the help window, depending on what it thinks you are
   doing. Right now you have a summary of the main function keys,
   plus a few other things.  Press F10 (without the Alt), and
   you'll get a summary of one-letter debugger commands.  Press
   F10 a second time and you'll get more one-letter commands, and
   some Ctrl-key commands, dealing with keystroke recording and
   playback. Press F10 a third time and you'll get a summary of
   the remaining Ctrl-key commands.  Finally, press F10 a fourth
   time to return to the function-key help screen.

6. Let's try an immediate assembly language instruction. Press
   the "M" key, which is the first letter of the immediate
   instruction MOV AX,123.  Note that the reverse video block
   jumps from the hash sign within the disassembly, down to the
   line just above the blinking cursor.  The block is the
   debugger's cursor; the blinking cursor is the program's
   console output cursor.  The debugger does not use the blinking
   cursor because we do not want the program's output to
   interfere with the debugger's output.  Also note that the help
   window is now telling you that you are typing in an assembly
   language line.

7. Complete the line MOV AX,123 followed by the Enter key (from
   now on I'll assume that you know that lines are followed by
   the Enter key, and that any periods at the end of a line are
   part of my sentence, and not part of what you type).  The
                                                               7

   debugger immediately executes the assembly language line you
   just typed, setting the register AX.  Note that you did not
   have to learn a debugger command for setting registers; if you
   know A86, you already know how to set registers!  The value of
   AX is now 007B, which may surprise you if you expected 0123.
   A86's default base is 10, so 123 was taken as decimal; which
   is hex 7B.  Type MOV AX,0123 instead, to get a value of hex
   123.

8. Let's now play with the flags display.  Type the line ADD
   AL,05D, which changes AL (the last two digits of AX) to hex
   80, and alters the flags to "o is a ".  The interrupt flag is
   still on; but zero and parity-even are now off.  They have
   been replaced by "o" overflow, "s" sign, and "a" auxiliary
   carry.

9. Type the line consisting of just CMC.  This is the Complement
   Carry instruction.  Observe that the "c" appears.  Notice also
   that the CMC that you typed remains on the screen.  Notice on
   the help window the entry "F3 RepeatCmd".  This tells you that
   the F3 key will repeat the last line command (not function
   key) that you typed.  Press F3 several times, to see the carry
   flag toggle on and off.  Isn't that the cleanest flags display
   you've ever seen?

10. Let's single step an instruction.  Press the F1 key.  This
    executes the program instruction, loading the SI register
    with TAIL_BUFF.  The disassembly cursor moves down to the
    next instruction.  Observe that SI has changed to 0081, which
    is the pointer to the invocation command tail, which should
    contain the string typed after HEXOUT: " 41 42 5A" followed
    by a carriage return code (hex 0D).

11. Let's examine memory to verify that last assertion.  Press
    the "1" key. The cursor jumps to the start of memory window
    1, and the help window gives you a huge choice of memory
    types to display.  The entry "ByteHex 2" tells us that "B"
    will cause hex bytes to be displayed.  The "2" indicates that
    the display occupies a fixed number of display bytes for
    every memory unit, namely 2 hex digits.  Type B followed by a
    comma, to indicate that you want nothing but hex bytes to be
    displayed. Now the help window asks for a segment location.
    Let's use the DS register: type DS followed by a comma. Now
    the help window wants an offset within the segment: type SI.
    Before typing the terminating Enter, backspace out what you
    have typed, and watch the help windows regress appropriately.
    Isn't that impressive?  Now retype the line, "B,DS,SI".  Note
    that when you press Enter, the line fills out with hex
    values: 20 34 31 20 34 32 20 35 41 0D etc.  (61 instead of 41
    is OK; it means you typed the invocation in lower case.)

12. Let's look at the same line, displayed as text.  Type "2",
    moving to memory line 2, then type the line "T,SI".  This
    time you specified type T for text, and you left out the
    segment register specification.  D86 uses DS when you leave
    out the segment register; so in this case you'll get the same
    segment. This time the display starts with "41 42 5AM"; the
    "M" is the carriage return, which is control-M, ambiguously
    displayed. You can read Chapter 6 later on for descriptions
    of all the types, including other text types allowing
    non-ambiguous displays.

13. Let's execute the next instruction, CALL GET_HEX.  Here we
    have a choice, between executing the procedure all at once,
    or stepping into the procedure to execute its instructions
    one at a time.  Let's try stepping in first: type the F1 key.
    The cursor jumps to location GET_HEX, on the same disassembly
    screen.  The SP register decrements from FFFE to FFFC, and a
    value 0106 appears on the stack.  This is the return address,
    pointing to the instruction following CALL GET_HEX.

14. Watch memory lines 1 and 2 as you press F1 again, single
    stepping the LODSB instruction.  You had set up the lines to
                                                               8

    be pointed to by SI.  Since SI changes when LODSB is
    executed, the memory displays advance to the next byte. Note
    that the AL register contains the value hex 20, a blank.

15. In a normal debugging session, we would continue stepping
    within GET_HEX, but let's not do that right now.  Instead,
    press the F6 "TrapRet" key, which starts the program going,
    trapping at the return address on top of the stack, which was
    0106.  The cursor jumps back up to location 0106, the value
    is no longer on the stack, and SI and the memory displays
    have advanced to 0084.

16. Let's try the classic "G" command, common to all debuggers.
    Type the line "G,0103", noticing the help windows as you go
    along.  After you press Enter, the program runs until it gets
    back to the trap address you provided, 0103. Note that the
    program has called OUT_VALUE to output the "A" that
    corresponds to your input hex 41.  The "A" appears on the
    bottom line, and the blinking cursor advances.

17. Let's execute the next CALL GET_HEX all at once, by pressing
    the F2 ProcStep key.  SI advances again, and AL is loaded
    with the next value 42.

18. Notice that the disassembly is symbolic: the display is CALL
    GET_HEX, not CALL 0112 as lesser debuggers might give you.
    Let's try symbolic input: type the line "B,HEX_DIGIT?",
    causing the debugger to set a fixed trap at location
    HEX_DIGIT?.  Now set your program running with a simple G
    followed by the Enter key.  The program traps at HEX_DIGIT?.
    Since this location is not in the disassembly window, the
    window is regenerated, and the cursor placed at HEX_DIGIT?.
    The memory displays now point to the final number "5A".

19. Press F3 to repeat the G-command.  The program traps at
    HEX_DIGIT? again, with SI advanced to the "A".  Press F3
    again; advancing SI to the final carriage return.

20. Press F3 yet again.  Since HEX_DIGIT? is never reached again,
    the program runs to its completion.  D86 automatically traps
    at the EXIT instruction: in this case, it is INT 021 with the
    AH register set to hex 4C, the function number for EXIT.  If
    we try to start the program again from here, we will be
    frozen here: we must issue the Q command to exit the session.
    Don't do it yet, though.

21. Before exiting, let's check out HEX_DIGIT? more thoroughly.
    First, we clear the breakpoint we set, by typing "B" followed
    by the Enter key.

22. Type the command line "J 0200", jumping to a scratch-pad
    memory area.  Then press the F7 key, entering Patch Memory
    mode.  The cursor moves into the disassembled instruction,
    signalling that whatever you type is clobbering it.

23. Type in the lines "INC BL", "MOV AL,BL", and "JMP
    HEX_DIGIT?".  Press Enter at the beginning of the fourth
    line, exiting Patch Memory mode.  The cursor will return to
    the left of the 0200 INC BL line.

24. Type the immediate command "MOV BL,'0'-2".  The BL register
    should change to the evaluated value, hex 2E.

25. Execute the patch subroutine by typing the line "CALL 0200".
    The value BL increments to 2F, which is one less than the
    lowest digit, '0'.  The Carry flag is set, indicating that
    HEX_DIGIT? has correctly judged 2F not to be a hex digit.
    Now press F3 repeatedly, executing your patched subroutine
    for each decimal digit.  The "c" will disappear as the values
    advance; and AL will hold the correct binary value for each
    hex digit BL.  When BL reaches 3A, the "c" comes back on
    again, indicating that we are beyond the decimal digits.
    When BL reaches 41, "c" goes off, and AL values of 10 through
    15 are displayed.  When BL reaches "47" "c" comes on yet
    again, because G is not a hex digit.  Type "MOV BL,05F",
    followed by "CALL 0200", followed by F3 several more times to
    verify correct action for the range of lower case 'a' through
    'f'. You have, relatively quickly, done a thorough test of
    HEX_DIGIT?.  How long would that have taken on a lesser
    debugger?

26. Type Q followed by Enter to exit the debugger.
                                                               9


CHAPTER 3   REQUIREMENTS AND OPERATION


System Requirements for D86

D86 currently requires either an IBM-PC or compatible computer, a
Texas Instruments TI-PC, a Wang PC, a Tandy 2000, a DEC Rainbow,
a Sirius/Vector 9000, a Zenith Z-100--ET-100, or a Sanyo 550 or
555 computer.  The computer must be running MS-DOS V2.00 or
later.  The IBM compatibility must exist at the BIOS and video
interface levels: D86 calls the BIOS to obtain keystrokes and
video status information; and, on an IBM-PC, D86 writes directly
to video memory at segment 0B000 (if the BIOS says monochrome) or
0B800 (if color).

If your MS-DOS machine is not one of the above-mentioned specific
models, chances are it's an IBM-compatible and you'll run D86
just fine.  For example, all of the "clone" computers released in
the last several years are IBM-compatible.  If it is one of the
above non-IBM models, D86 has special BIOS code for your
computer, invoked via the +B switch described the section "BIOS
Switching" later in this Chapter.

D86 is fairly flexible about memory management.  If there is
enough memory, D86 will take the combined sizes of D86.COM and
A86.COM (currently about 51K bytes), plus 64K bytes for its own
stack, and leave the rest for the program being debugged.  If
memory is tight, D86 will reduce the memory allocated to its own
stack, down to a minimum of 16K bytes.  The segment occupied by
the program being debugged will be similarly reduced.  If the
program is a COM file, you can tell this by the initial SP value,
which is 0FFFE if there is a full 64K, less if there isn't.
Thus, D86 will work with as little as 70K bytes beyond the
operating system; but the symbols capacity and the program's
memory will be severely limited in that case.  It is best to have
at least 166K bytes of memory available when D86 is running.


Invoking D86

You invoke D86 by issuing the command

   D86 [+Bn] [+V] [progname [command-tail]]

where progname is the name of the program you are debugging.  In
other words, you type a program invocation line just as if you
were about to execute the program without a debugger, except that
you append D86 before the line.  The B and V switches can appear
in either order.

The following sections describe in detail the elements of the D86
invocation line, and how D86 acts on them.


Finding the Program File

On most other debuggers, you have to give the full file name,
with an explicit extension and a specific directory.  With D86,
you don't: D86 uses almost the same algorithm for locating a
program file that COMMAND.COM does:

1. Look for COM, then EXE, then BAT in the current directory.

2. Look for COM, then EXE, then BAT in each directory in turn
   given in the PATH environment variable.

The one difference is that D86 will look only for one extension
if you give an explicit extension (and it doesn't have to be COM,
EXE, or BAT).  COMMAND.COM ignores the extension you give -- I
thought that was just too absurd, and didn't duplicate it.

A strange feature that I did duplicate is COMMAND.COM's lack of
concern for whether the program is named COM or EXE.  If the
program file begins with a valid EXE header, it's treated as an
EXE no matter what it is named.  If not, then it's treated as a
COM file.

D86 provides limited support for BAT files.  (That's better than
other debuggers, which provide no support.)  If your program is a
BAT file, D86 reads the first line of the file and pretends that
that was what you typed following "D86" in your invocation.  The
D86 status screen (gotten via Ctrl-S) gives you this line, and
tells you what BAT file it came from.

The BAT file limitations are that D86 doesn't skip over remark
lines, doesn't substitute batch-file parameters, and doesn't
perform console redirection specified in the batch-file line.

You can also invoke D86 with no progname.  The debugger comes up
with no program loaded, allowing you to simply poke around the
machine.

If D86 had a problem loading your program, you'll see all NOPs in
memory instead of instructions.  You can type Ctrl-S to get the
status screen that tells you what the problem was.


Finding the Symbols File

D86 is a symbolic debugger.  It uses a special .SYM file produced
                                                              10

in one of three ways:  First, if your program was produced by
A86, then the .SYM file was produced by A86 at the same time.
Second, if your program was produced by a high-level language
such as Pascal or C, you can feed the linker's .MAP listing to
the special MAPD86 tool, available to registered D86 users only.
Third, you can "reverse engineer" a program by adding symbols
while in D86's patch mode, then create a .SYM file with D86's W
command.

When invoked, D86 looks for a file with the program's name and a
.SYM extension.  D86 first looks in the current directory for
this file, and then in each directory specified in the PATH
environment variable.  It is not necessary for the SYM file to
exist.  If there is no SYM file, the debugger simply runs with no
user symbols defined.  You'll also get no user symbols if the SYM
file was not of a correct format (it wasn't produced in one of
the ways mentioned in the previous paragraph, or it has been
corrupted in some way).  If you were expecting symbols and didn't
get any, you can press Ctrl-S to get the status screen that tells
you what the problem was.


BIOS Switching

Some of the non-IBM computers named at the start of this chapter
are automatically detected by D86, so you shouldn't need any
special action to use D86 with them.  Others have no obvious
identifying features to them, so that you need to tell D86 that
you're using that computer.  You do so with the switch +B
followed by a machine number, as follows:

   +B4     for the IBM-PC      (automatic) +B5     for the
   Wang-PC      (automatic) +B6     for the Texas Instruments PC
   (automatic) +B7     for the Tandy 2000      (automatic) +B8
   for the Sanyo 550 or 555 +B9     for the Sirius/Victor 9000
   +B10    for the DEC Rainbow      (automatic) +B12    for the
   Zenith Z-100 and ET-100

Machines marked "automatic" are automatically detected by D86, so
you shouldn't need the B switch for them (but I give one anyway
just for safety).

For example, if you're running on a Sanyo, you invoke D86 via

   D86 +B8 progname

Incidentally, the Sanyo interface is of interest because the BIOS
is IBM-compatible but the video isn't.  So invoking +B8 causes
all video output to go through the BIOS, which is slow but it
works on all IBM compatibles as well.  So if D86 doesn't work on
your BIOS-compatible machine, you can try the +B8 switch.


The D86 Environment Variable

You can make your +B setting (and, for that matter, a +V setting)
automatic by placing it into a DOS environment variable called
D86. For example, if you run on a Sanyo, you issue the command

   SET D86=+B8

to the DOS prompt.  You can make the setting permanent by placing
the above line into the AUTOEXEC.BAT file on your system disk.


Two-Screen Debugging with +V

The +V option can be used if you have both a monochrome and a
color monitor.  You invoke D86 when the operating system is on
one monitor -- with the +V switch, the debugger will appear on
the other monitor, and program console output will appear on the
operating system's monitor.

In order for the +V option to work, you must initialize both
screens by MODEing to them sometime after powering up the
machine. You should also make sure that the blinking cursor is at
the bottom of the screen on which the debugger will appear (the
simplest way to do this is to type Enter until the prompt gets to
the bottom).  If you can suppress the blinking cursor, that's
even better.  See in your DOS operating manual for instructions
on how to use MODE to switch between screens.  D86 doesn't do the
initialization, because I couldn't figure out how to get the BIOS
to do so without blanking the screen, and you might not want the
screen blanked every time you start a D86 session.


The D86 Screen Display

When D86 starts up, it generates a full-screen display, and
awaits your debugger commands.

In the top part of the screen is a symbolic disassembly of the
A86 program, with the screen cursor positioned next to the
instruction pointed to by the 8086 instruction pointer.

In the lower left corner is a fixed display of the complete 8086
register set.

At the top of the second column of the register-set display is a
                                                              11

display of the 8086 flags.  Each flag displays as blank if the
flag is off; a lower case letter if the flag is on:

     o   for overflow,
     d   for direction,
     i   for interrupts enabled,
     s   for sign,
     z   for zero,
     a   for auxiliary carry,
     e   for parity even, and
     c   for carry.

Across the bottom line of the screen is a display of the contents
of the user stack.  The display begins next to the SP register
value, with the number of elements on the stack.  (The stack is
assumed to have 0 elements when SP is at its original value,
which is 0FFFE for COM files, and a value specified in the header
record for EXE files). The number of elements is followed by a
colon, followed by as many of the top stack elements as fits on
the line.  The initial display will have zero elements; nothing
is yet on the stack.

To the right of the registers are 6 lines, numbered 1 through 6.
On these lines, you can generate windows into 8086 memory,
displaying bytes, words, or ASCII text in a variety of formats.
The windows can be located either at absolute memory locations,
or be pointed to by any of the 8086 registers.  The commands you
issue to generate these windows are described in Chapter 6.


D86 Commands

There are 5 kinds of activities you perform in D86:

   1. Issuing assembly language commands for immediate execution

   2. Issuing debugger commands via lines that begin with a
      single letter

   3. Issuing debugger commands via the function, Ctrl, and
      cursor-control keys on your keyboard

   4. Setting up windows that display memory

   5. Issuing assembly language commands to enter into memory
      (PatchMem)


Immediate Assembly Language Commands

A primary part of the D86 command language is the A86 assembly
language. With it, you can jump to different areas of your
program, set your registers, perform arithmetic, and call any of
the procedures of your program.  Simply type in any legal A86
instruction, and it will be executed immediately.

JMP and RET instructions cause the program counter (and thus also
the disassembly) to move to the indicated destination.  CALL
instructions cause the entire procedure to be executed.

WARNING: The immediate-execution feature is a little tricky if
you are in a multi-segment program, or if you jump to exotic
parts of the 86 memory space (i.e., into MSDOS, ROM, video
memory, or the interrupts table). This is because D86 needs a
buffer in which to put the immediate-execution command.  The
buffer should be in your program's CS segment, so that commands
such as jumps and near calls execute correctly.  So D86 must
always search in CS for a satisfactory buffer.  Here is how D86
finds it:

  1. If you declare a label D86_BUFFER, pointing to a buffer
     within your program, then D86 will use that buffer as the
     offset for its immediate instruction.

  2. If not, then if the program's CS register is the same as its
     SS register, D86 will use (SP-300) as its immediate buffer.
     Thus, your stack should have plenty of room (a good practice
     in general).

  3. As a last resort, D86 uses offset 00E0, which points to the
     last 32 bytes of the Program Segment Prefix (PSP).  In that
     case, if you were to issue an immediate command that reads
     from a disk file, you would be in trouble, because the
     disk-read operation clobbers the PSP, and the command would
     not be trapped back to the debugger.

  In cases 1 and 3 above, the segment containing the buffer is
  the program's CS segment, unless that is out of range (below
  the program's original CS, or above the top of available
  program memory).  If the program CS is out of range, the
  program's original CS is used instead.  In that case, immediate
  instructions such JMP, RET, and CALL will not work correctly.

  Note that the above caveats do not apply to single stepping.


Entering Instructions Into Memory

D86 allows you to alter 8086 memory in two ways: first, you can
issue immediate assembly language commands which, when executed,
                                                              12

store values in memory.  The other method is to enter a special
mode, in which you enter instructions directly into 8086 memory.

You enter this mode by typing the F7 (PatchMem) key. The screen
cursor jumps from the left edge of the line at the current
program counter, into the middle of the line where the
instruction is.  You start typing over the instruction, to signal
that you are clobbering the instruction that was there.  If you
did not intend to enter this mode, you can backspace back to the
start of the instruction, and type a carriage return.

Each line you type in is checked for errors.  If there was an
error, a message is displayed, the cursor remains at the same
location, and you try again. If there was no error, the cursor
moves beyond the newly-assembled line, and you can type in
another line.

To exit the memory programming mode, you type any of the control
key commands at the beginning of the line.


Entering Data into 8086 Memory

You can deposit data into the 8086 memory space by using the
programming mode described in the above section.  Simply enter DB
and/or DW statements instead of instructions.  Note that ASCII
strings can be entered with the DB instruction; and that arrays
can be initialized via the DUP operator in a DB or DW statement.


Adding Symbols to a Program

Patch mode also allows you to do something that you cannot do in
immediate execution mode: add symbols to the program.  You can do
so by either:

   1. Typing in a new symbol name, followed by a colon; or

   2. Typing in an EQU directive.

There are several uses for this.  First, you might want to create
an abbreviation, by equating a short name to a long one, or to a
hard-to-remember constant value.  Second, you might want to
"reverse engineer" a program for which you have a .COM file, but
not the A86 source code.  Each time you add a label, the
disassembly becomes more readable.  Third, you might want to
label code that you have added in patch mode.

After you have added symbols to the table, you can save the
resulting expanded table with the W command.  Simply type W
followed by the Enter key at the main debugger command level.

Forward referencing is allowed when you are in patch mode.  You
must be careful, however, to resolve any forward references you
have made, before leaving patch mode.
                                                              13


CHAPTER 4    D86 CONTROL KEYS

D86 has a set of functions invoked by single keys.  Keys which
switch the display (for example, to show a help screen) can be
pressed in any context, to be acted upon immediately.  Other
keys, such as the single-stepping keys, can be invoked any time
D86 is awaiting the beginning of an assembly language command.


Display Control Keys

There are numerous keys that let you control the switchable
window in the upper right corner of the screen.  The F10 and
Alt-F10 keys let you toggle between windows, giving you a "tour"
of what's available.  Various keys accessed by using the "Ctrl"
key as a shift key let you move directly to the window of your
choice.

The keys in this section are acted upon in any debugger context,
whether you are in the main command mode or in the middle of one
of the other modes (typing in a debugger command, an
immediate-execute line, a patch-memory line, or a memory window
specification):

Alt-F10   Toggles you between Help and Non-Help modes.  If the
          window is showing you a help page, it will switch to
          the last Non-Help page that was displayed.  If not, the
          window switches to the last Help screen displayed for
          the current context.

F10       In non-help mode, toggles you between the available
          non-help windows: the sign-on/second disassembly
          window, the status window, the memory display window,
          and, if you have a floating-point chip, the
          floating-point display window.

          In help mode, toggles you between the help windows
          available in the current context.

Ctrl-I    (or TAB) takes you from any other window directly to
          the sign-on/second disassembly window.  This window
          contains the D86 sign-on message until the first time
          that the Instruction Pointer leaves the first
          disassembly page.  From that point on, the sign-on
          message is no longer available, and you get a second
          disassembly page instead.

Ctrl-S    Takes you from any other window directly to the
          debugger status window.

Ctrl-F    Takes you from any other window directly to the
          floating point display window, if your machine has a
          floating point chip in operation.  If not, this key is
          ignored.


If your CPU has the MMX, Pentium 3, and/or the AMD 3DNow
instruction sets, you can see a display of the associated
register sets by pressing Ctrl-F repeatedly: multiple pressings
will rotate you through all the special-register displays
available on your machine's processor.

Ctrl-N    If you have a memory display window in sight, this key
          advances to the Next window full of memory.

          If you do not have a memory display window, but do have
          at least one memory line specification, this key takes
          you from any other window to the memory display window,
          continuing from the end of the last line display.

          If you have no memory line specifications set up, this
          key is ignored.

Ctrl-P    If you have a memory display window in sight, this key
          retreats the pointer to memory displayed, by the amount
          displayed in the window.  If all the memory formats
          specified generate a fixed-size display (such as the
          B,W,T formats), then this will effect a "Previous page"
          function.  If there are formats producing a
          variable-size display (such as the N,D,C,S,L formats),
          then the retreat will be a probably imperfect
          approximation to an appropriate "Previous page" amount.

          If you do not have a memory display window, this key
          will go to one, just like the Ctrl-N key.

Ctrl-Q    If you are not displaying a help window, this key takes
          you to the last help window that was displayed for the
          current context.  If you are already displaying a help
          window, this key toggles through all the help windows
          available for this context.


Instruction Pointer Positioning Control Keys

All the remaining keys in this chapter can be invoked any time
the debugger is in its main command mode, awaiting the first key
                                                              14

of a debugger command or immediate assembly line.  They change
the value of the Instruction Pointer (IP register), and thus they
change the disassembly display.

None of the control keys in this section cause any program code
to be executed, other than the equivalent of a JMP instruction,
to the place that the disassembly cursor winds up.

WARNING: On some debuggers, you can change the location of what
is being disassembled without changing the IP register value.
I've decided on a "what you see is what you get" philosophy,
since you may well be moving the IP cursor to effect a jump in
the program (for example, you might use the Down-Arrow key to
experimentally skip over the execution of one or more
instructions in the program).  If your intention was just to look
around the program before continuing execution at the place you
left off, you may use the Home key to return to the place where
execution last halted.

Down-Arrow   Jump to the instruction following the current one.
             Visually, the disassembly cursor moves down by one
             instruction line.

Up-Arrow     Jump to the instruction preceding the current one.
             Visually, the disassembly cursor moves up by one
             instruction line.  NOTE that the implementation of
             this function is a little tricky, since it's
             impossible to reliably disassemble backwards.  What
             D86 does is retreat a fixed, fair-sized distance,
             disassemble forward until the current instruction is
             reached, and take the instruction disassembled just
             before the current one.  If there is non-instruction
             code in memory shortly before the current position,
             the synchronization may fail, and this instruction
             may put you in the middle of a previous instruction
             instead of the beginning.  If this happens, you may
             adjust by using the Ctrl-D or Ctrl-U keys.

Ctrl-D       This key is identical to the Down-Arrow key, except
             the jump forward is just one byte, instead of a full
             (usually multibyte) instruction.  (IP is
             incremented.)  You use this key when you think
             you've landed in the middle, rather than the start,
             of an instruction.

Ctrl-U       This key decrements IP, moving the cursor "Up" by
             one byte's worth.  Like Ctrl-D, it is used to
             manually synchronize disassembly.

PgDn         Jump to the next disassembly page, at the memory
             location immediately following this page.  Repeated
             pressing of this key allows you to scan program code
             quickly.

PgUp         Jump to the previous disassembly page, ending with
             the instruction just before the top instruction on
             the current page.  NOTE the warning given with the
             Up-Arrow description, about possible synchronization
             problems, applies here as well.

Home         If you have moved the IP cursor since the last
             program instruction executed, then this key returns
             IP to that spot.  If you are already at that spot,
             this key returns you to the program's starting
             location.  For COM files, this is always location
             0100 in the original code segment.  For EXE files,
             this location was derived from the EXE header
             record.  Note that repeated pressing of Home will
             cause IP to alternate between the two locations, so
             you can't mess yourself up by pressing the key one
             too many times -- just press it again.

Ctrl-E       Jump to the End of the program, as determined when
             it was loaded, and possibly advanced if the program
             was patched from the end.


Program Execution Control Keys

Ctrl-X       Single step the current instruction.  If the
             instruction is a call, go into the procedure to
             single step it.  If you want the entire procedure
             executed on a single keystroke, use the F2 key.

F1           Single-step the current instruction just like the
                                                              15

             Ctrl-X key, except that INT instructions are
             executed all at once, not stepped into.  This
             exception was added with D86 V3.21, because stepping
             into DOS or the BIOS is a hazardous operation,
             likely to crash the computer.

F2           Procedure step: same as single-step, except that if
             the current instruction is a CALL, the procedure is
             executed in one step; or if it is a repeated string
             instruction, the operation is executed all in one
             step.  In older versions of D86, the F2 key trapped
             at the next instruction -- that is now done by the
             F5 key.

F4           Start the program, setting a trap at the destination
             of the conditional jump instruction currently
             pointed to.  If we are not pointing to a conditional
             jump, then we single step.

F5           Trap next: start program, trapping at the
             instruction following the current one.  This can be
             used as well as F2 to execute procedures and string
             operations in one step.  But this command key, when
             pressed at a LOOP or conditional jump instruction,
             will also allow you to break out of a loop.

F6           Start the program, setting a trap at the address on
             top of the stack (hopefully a procedure return
             address).

F9           Go until here: Start the program from the point at
             which it last stopped, setting a trap at the current
             CS:IP location.  If you didn't move the IP cursor
             since the program stopped, this will simply tell the
             program to go until the next time this same point is
             reached.  If you did change IP, (for example, if you
             paged forward to find an interesting section of
             code), this command saves you from having to go back
             and single-step up to this point.


Special Action Control Keys

F3           Repeat the last typed-in assembly language or
             debugger command

F7           Enter the Patch Memory mode, described in Chapter 3.

Shift-F7     Mark the current CS:IP memory location, for use by a
             following F debugger line command.  F can either
             return to this location, or find memory bytes that
             match the ones at this location.

Ctrl-M       Mark the current location in the keystroke-recording
             file, so the next keystroke-save operation will
             begin with the next keystrokes you type.  See the K
             command in Chapter 5 for details.

Ctrl-R       Re-do a previous keystroke retracted by a previous
             Undo command (described in Chapter 5).

Ctrl-T       Reset the debugger's internal Top-of-Stack pointer
             to the current SP value.  This will cause the
             current stack display to become empty, so that
             subsequently pushed values will appear by themselves
             on the stack display.

Alt-x        Play back the ALTx.D8K keystrokes file.  See the K
             command in Chapter 5 for details.
                                                              16


CHAPTER 5   COMMAND LANGUAGE

In addition to immediate-execution assembly language commands,
there is a set of commands recognized by the debugger.  They are
identified by the first keyword on the line being a single letter
(i.e., the second character of the line is a non-letter, usually
a comma or Enter).


General Operands to Debugger Commands

Most of the debugger commands consist of their single-letter
identifier, followed by a comma, followed by one or more general
operands, separated by commas.  General operands can be one of
the following:

   a. a numeric constant, whose format is just as in the assembly
      language (leading zero means default hex, otherwise default
      decimal)

   b. a register name

   c. a user symbol from the assembly language program being
      debugged.


Format of Debugger Command Examples

Many of the examples given below will be given in double quotes.
Note that the double quotes are not part of the command.  You are
encouraged to try out the example on the debugger, by typing the
string within the quotes, not including the quotes, and always
followed by the Enter key. Note further that the double-quoted
string may be broken across two lines of this manual, but that
does not mean you should type an Enter where the string is broken
-- debugger commands always consist of a single line, always
terminated by Enter.


The Debugger Command Set

Following is a description of the debugger commands recognized:

B  sets and clears the fixed breakpoints of the program.  The
   debugger has four breakpoints.  Two are transitory; they are
   automatically cleared after each return from the program to
   the debugger.  They can be set by the G command. The other two
   are fixed -- they will remain in effect until you explicitly
   clear them.  The fixed breakpoints are controlled by this B
   command.

   You follow the B with zero, one, or two general operands.  If
   there are zero operands (the B is followed immediately by an
   Enter), then both fixed breakpoints are cleared.  If there are
   one or two operands, then the fixed breakpoints are set to the
   operands.

   Note that previously-set breakpoints can be implicitly
   cleared, by overwriting them with other breakpoints.  If your
   B command has one operand, and there was one breakpoint
   previously set, the debugger sets the unused breakpoint, so
   that both remain in effect.  If your B command has one
   operand, and both breakpoints were previously set, the most
   recently set breakpoint is saved, and the older breakpoint is
   overwritten.

   The status screen, displayed by typing Ctrl-S, shows you the
   B-command breakpoints in effect.

   Examples: if you type "b,numout", the debugger will set a
   breakpoint at location NUMOUT, which should be a label in the
   program being debugged. You may start and stop the program
   many times, and the breakpoint will stay there.  You may even
   allow the program to stop at NUMOUT repeatedly; the breakpoint
   is not cleared even if the program stops there.  If you
   subsequently type the command "b,01000", then there will be
   breakpoints at both NUMOUT and location hex 01000.  If you
   then type "b,01200", the first breakpoint NUMOUT is
   overwritten; the two breakpoints now in effect are 01000 and
   01200.  The 01000 breakpoint will be next in line to be
   overwritten.  You may clear both breakpoints by typing "b".
   There is no way to clear one breakpoint at a time.


D  sets or clears a data breakpoint.  This command is available
   only to registered D86 users running on a 386-or-later
   machine. A data breakpoint causes the program to trap to the
   debugger whenever a specified memory location is accessed.
   The trap occurs after the instruction causing the access, so
   you should press the Up-arrow key to see the instruction.

   You follow the "D" with a comma, followed by a specification
   parameter.  The parameter consists of up to three characters,
                                                              17

   at most one each from the following categories:

   1. A letter giving the size of the memory element being
      checked: B for byte, W for word, D for doubleword, or a
      minus sign if you are clearing the breakpoint.  Default is
      B.

   2. The letter R if you wish to trap if the memory location is
      either written to or read from.  If you leave the R out,
      the trap will occur only if the memory location is written
      to.

   3. A digit, (0,1,2, or 3) giving the number of the 386
      breakpoint register you are using to set the trap.  Default
      is 0.

   You terminate the specification parameter with a comma, then
   provide one or two numbers to specify the memory location you
   are trapping. If you provide two numbers, the first is the
   segment register value and the second is the offset.  If you
   provide only one number, it is the offset -- the value of DS
   is used as the segment register value. As with all value
   parameters in D86, you can give a register name or a label
   instead of a number.  You can also leave out the address
   entirely, to preserve the previous address setting of that
   breakpoint register.

   Note that the 386 requires Word and Doubleword breakpoints to
   be aligned in memory.  If you provide an odd address for a
   Word breakpoint, the 386 will ignore the bottom bit of your
   address.  Similarly, the 386 will ignore the bottom two bits
   of your address for a Doubleword breakpoint.

   Examples: D,R1,ES,0400 sets a byte data read-or-write
   breakpoint, using the 386's register number 1, at memory
   location ES:0400.  D,-1 would clear that breakpoint.  D,R1
   would set it again with its previous value.  D,W,MY_VAR sets a
   Word breakpoint, using the 386's register number 0, at
   location DS:MY_VAR -- the trap will occur if either byte of
   the variable MY_VAR is written to (but MY_VAR should be
   aligned to an even address for this to work).

   If the D command is enabled, you'll get a one-line display of
   the data breakpoint registers in the status window (invoked
   via Ctrl-S).  The registers are presented in order: 0,1,2,3.
   The breakpoint type is given, followed by the 5-digit absolute
   memory address of the breakpoint.


F  finds a string of memory bytes.  The memory to be searched
   starts at the current CS:IP location.  The string being sought
   is contained in memory at the CS:IP location marked with the
   last Shift-F7 command.  The number of bytes in the target
   string is given as the first operand to the F command.  For
   example, "F,1" finds the next instance of a single byte value
   after the current CS:IP.  If the marked location points to a
   NOP, "F,1" will find the next NOP code.

   If you provide a second operand to F, it is a "retreat
   number".  For example, "F 2,10" assumes that you are looking
   for a 2-byte sequence, and you have retreated 10 bytes from
   the starting location for your search.  When the string is
   found, F will retreat 10 bytes from that string.  That way you
   can view the instructions that preceded the found string.  I
   use this feature when I am searching for BIOS and DOS
   interrupt calls in a program.  I want to retreat before the
   calls, to see what function numbers were loaded into
   registers.  I can use the F3 key to repeat the searches,
   giving me a sequence of disassembly displays with the
   interrupt in the middle.

   F with no operands returns CS:IP to the marked location, in
   case you want to use F7 to deposit another string to be
   searched.

   If you have never pressed Shift-F7 in this session, the marked
   location is 0C000 of the program's starting segment.  That's
   often a good "scratchpad" area for small programs, far from
   both the program and the stack.


G  starts the user program.  You can give one or two operands to
   G, specifying locations within the program at which you wish
   to return to the debugger.  These are "transitory
   breakpoints"; both of them are cleared when the program
                                                              18

   returns to the debugger for any reason.

   Whenever you start the program, at least one instruction from
   the program will be executed, even if there is a breakpoint at
   the current instruction pointer location.  This means you can
   set a breakpoint at the current location; instructing the
   program to return to the debugger the next time it gets back
   to the current location.


J  jumps to the location indicated by the operand, within the
   current code segment.  J is useful when you are exploring
   memory outside of your program's memory area.  In that case,
   the immediate JMP command is executed from a buffer within
   your program's original code segment.  JMP would therefore
   return you to that segment.  J will keep you in the distant
   segment.


K  allows you to save and play back D86 keystroke scripts.  D86
   records in memory all keystrokes (up to a limit of 1024) you
   type to the debugger, and lets you save those keystrokes in
   files, and recall them, in several different ways.  All D86
   keystroke script files have the extension D8K in their names.
   If D86 finds a script file whose root name is the same as the
   program being debugged, D86 will automatically play back that
   script as soon as it starts up.  You can use this feature to
   set up files (with the S command), set up memory displays, and
   step to the area of your program you are concentrating on,
   avoiding repetition every time you enter the debugger.  If you
   specify D86 without a program name, D86 will look for a script
   named NULL.D8K.  In either case, if D86 does not find the
   progname.D8K file, it will look for a file named D86.D8K and
   run that.  This allows you to set up a global-default
   keystroke script, to be used to start every debugging session.
   During a debugging session, you can play back keystroke
   scripts from the debugger command line with the K,P command
   described shortly, or at any time by pressing the Alt key
   together with any letter key. For example, Alt-L pressed at
   any time will play back the ALTL.D8K script.

   You can mark the beginning of the keystrokes to be saved in
   one of several ways.  The K,F command will flush all recorded
   keystrokes from D86's memory buffer, letting you "start
   fresh".  The S,F command also does this; it resets the entire
   debugging session as well (cancelling the effects of any
   default scripts or manually-typed keystrokes).  The Ctrl-M key
   can be typed in any debugger context to mark the beginning of
   keystrokes to be saved by the next save command, without
   actually flushing the previous keystrokes -- the debugger
   remains in whatever context it was in, the marker will revert
   to the start of the session after the next keystroke-save
   operation, and the Undo command will play back from the start
   of the session.

   The command K,S,filename will save debugger keystrokes in a
   file named filename.D8K ("filename" can be any name you wish,
   and you do not need to explicitly give the D8K extension in
   the command).  The file will begin with keystrokes marked by
   the last command described in the above paragraph; if no such
   specification was given, the file starts at the beginning of
   the entire debugger session. Commands and keys dealing with
   keystroke scripts are not themselves recorded.  If you issued
   a previous playback command, or if a playback occurred by
   default, the keystrokes from those playbacks are included as
   if you had typed them manually.

   Alternatively, you can save ALTx.D8K files from any debugger
   context by pressing the Ctrl-K key, followed by the Alt-key
   you wish to associate with the key sequence.  For example,
   suppose you wish to save the keystroke sequence for the
   memory-window specification for a complicated structure.  You
   wish the sequence to include the format of the structure, but
                                                              19

   not its location-specification.  You can do this by pressing
   Ctrl-M to mark the beginning of the recording, the digit 0 to
   move to the beginning of the first free memory window, the
   specification (e.g., B3WB1,), the Ctrl-K key, and the Alt-S
   key.  The debugger silently saves the keystroke sequence in a
   file called ALTS.D8K.  From now on, whenever you type the
   Alt-S key, the keystrokes 0B3WB1, will be played back, leaving
   you ready to type only the location where you want the memory
   structure to be displayed.

   The command K,P,filename will play back the keystroke script
   file filename.D8K that you previously saved.  This form, while
   more cumbersome to invoke, allows you to use a greater variety
   of file names.  All keystroke playback files can be either in
   the current directory, or any directory named in your PATH
   environment variable.


L  creates a disassembly listing, with addresses, hex bytes, and
   disassembled code.  You can output either the entire COM
   program, or a section of memory beginning with the current
   CS:IP location.  You omit the first operand if you want the
   entire COM program.  If you want a section of memory, you
   provide the offset beyond the memory section as the first
   operand.  You give the name of the output file for the listing
   as the second operand.  If you omit the second operand, the
   listing goes to the printer.  Examples: L,,FOO.LST outputs the
   entire COM program to FOO.LST.  L,0200,SEG.LST outputs the
   section of memory from CS:IP up to CS:0200 to SEG.LST.


O  sets a special fixed breakpoint.  Whenever your program calls
   MSDOS via INT 021, the debugger will monitor the function
   number passed in the AH register.  If the function number
   falls within the range specified by this command, the program
   will trap back to the debugger.  If you give two operands to
   O, the operands are the lower and upper bounds for the range
   of trapped functions.  If you give one operand, only that
   function number will be trapped.  If you give no operands, any
   previous O-trap setting is cleared.

   For example, note that function 3F hex is the READ function
   for MSDOS version 2.  If you want to trap whenever this READ
   function is invoked, you can issue the command O,03F and then
   start up your program with the G command.  Another example:
   suppose you want to insure that a program does not make any of
   the new Version 3 DOS calls, 59 hex and above.  You can issue
   the command O,059,0FF and then start your program.

   NOTE: if the second operand is less than the first, then the
   range wraps around through zero.  For example, O,059,030 traps
   on 059 through 0FF, and also 0 through 030-- both version 3
   and version 1 calls.

   SECOND NOTE: The EXIT function, hex 4C is always trapped by
   D86, regardless of your O-command settings.  The only way you
   should be able to exit from D86 is via the Q-command.  (If you
   do succeed in exiting some other way, I want to hear about it.
   In that case, D86 will become very confused if you reinvoke it
   before rebooting the computer.)


Q  exits the debugger and goes back to the operating system.


S  performs system functions, letting you bring your computer to
   a known state before debugging.  If the program you are
   debugging changes the contents of files on your computer, you
   may wish to begin your debugging session by restoring modified
   files from backup copies, and deleting any newly-created files
   from previous debugging sessions.  You can then save these
   commands in a keystroke script (see the K command), or perform
   an Undo command.

   The command S,C,srcfile,destfile copies the file named
   "srcfile" to the file named "destfile".  The command
   S,D,filename deletes the file named "filename".  The command
   S,R resets the debugging session: all open user files are
   closed, standard input and output are "rewound" if they had
   been redirected to disk files, the current drive and directory
   are restored, the debugged program is is reloaded from the
                                                              20

   disk, and the default keystroke script, if any, is rerun.  The
   command S,F does the same as S,R except the keystroke script
   is not rerun: this allows you to redefine what your starting
   script will be.


U  performs an "Undo" command by resetting and replaying your
   entire debugging session, except for the last commands.  The
   command U without any operands will retract a single command.
   The command U,number will retract the number of commands
   indicated.  For the purposes of this count, each full line
   typed to the debugger counts as a single command.  If you give
   a number bigger than the number of commands thus far issued,
   D86 will retract to the beginning of the debugging session.
   Retracted keystrokes can be replayed by pressing the Ctrl-R
   key (R stands for "Redo") repeatedly.


W  writes the program (if it was a COM format) and the symbol
   table back to the disk.  In this present version, you don't
   have any options as to what to name the files.  The program
   name given when D86 was invoked is always used, except that
   the files are always written to the current directory.  The
   program file has the same extension as the file that was
   loaded, and the symbols file has the SYM extension.

   D86 writes the program from location 0100 in the original code
   segment, up to the end-of-file location saved when the program
   was loaded, and possibly extended by a patch-memory operation
   while at the end of the program.  Any symbols added while in
   the patch-memory mode are saved in the symbols file, so that
   you can "reverse engineer" programs for which you do not have
   source, and save the symbol table results you have gleaned.
                                                              21


CHAPTER 6   MEMORY DISPLAY OPTIONS


Memory Display Windows

The debugger allows you to set up windows into your program
memory space. Using these windows, you can view memory in a
variety of formats.  The windows will remain in effect until you
cancel them; updating themselves automatically if the memory
changes.

There are six single-line memory windows always present, in the
lower right portion of the screen.  In addition, you can have the
upper-right window display a 14-line page of memory values.


Single-Line Memory Windows

A single-line memory window line consists of a specification,
typed in by you, followed by a display, supplied by the debugger.

To type in a specification on any one of window lines 1 through
6, simply type the associated digit, 1 through 6, when the
debugger is in its main command mode.  You can also specify the
first blank window line by typing the digit 0 (providing some
flexibility for keystroke scripts).  The cursor will jump to the
beginning of the memory-window line you are specifying.  You then
type in a display format specification, followed by the address
of memory you want displayed.

The simplest form of the display format specification is a single
letter, signifying one of the display types available.  The
choices are:

   B       for hexadecimal bytes
   W       for hexadecimal words
   N       for decimal bytes
   D       for decimal words
   Q       for octal bytes
   O       for octal words
   T       for text; each byte reduced to one ASCII display character
   A       for ASCII text, each byte occupying 2 display characters (the
                    exact display is spelled out later in this chapter)
   C       for ASCII text, occupying 2 bytes if needed, otherwise one

A format specification of one of the above letters will cause the
debugger to display the array of bytes starting at the address
you specify, in the format indicated by the letter, as long as
there is room on the line. All letters in a format specification
(or in any other context in the debugger) can be typed in either
upper or lower case.

The format specification should be terminated by a comma.  After
the comma (and an optional space), you type the address of memory
you want displayed. This consists of two values, the segment
followed by the offset.  The values should be separated by a
comma. You can omit the segment value if you wish: in that case,
the current value of DS is used. The debugger reminds you that
you have specified this option by following what you type with 2
commas instead of one.

The value you type can take one of the following forms:

   a. a numeric constant, whose format is just as in the assembly
      language (leading zero means default hex, otherwise default
      decimal)

   b. a register name (IP is now accepted as a register name)

   c. a user symbol from the assembly language program being
      debugged.

After you type the address specification, you hit the Enter key,
and the debugger fills out the rest of the line with the memory
display.

For example, if you want to display hex bytes starting at 01000
hex on display line 2, you type 2b,01000<Enter>. The cursor jumps
to the line immediately when you type the 2, and it displays the
b,01000 on the line as you type it.  The b says you want hex
bytes, and the 01000 has a leading zero to signify a hexadecimal
address, not decimal.  When you press the Enter key, the debugger
displays two commas, followed by the hex bytes.  If the memory is
zeroed, you will see 00 00 00 00 00 etc. to the end of the
display line.


Erasing Memory Display Lines

Any memory display window that you specify will remain in effect,
always updated to show the latest memory contents, until you
explicitly erase it. To erase a window, you type the number of
the window, followed by a blank.  The line will also be erased if
                                                              22

you start typing a format specification, and you hit the Enter
key before you get to your address specification.

In the coming sections, many of the examples assume (and they say
so) that your display is blank before you type in the example.
You can always get a blank display by typing in each number
followed by a blank: "1 2 3 4 5 6 ".

If you accidentally type a digit and DON'T want to erase the line
your cursor has jumped to, press the Esc key to return to the
main command mode.


Continuation Lines

You may continue a memory display window onto the next line, by
placing a double quote mark " at the beginning of the next line.
You may do this in one of two ways: you may type the number of
the next line, followed by the double quote mark; or you may
simply type the double quote mark at the command level.  The
first method allows you to specify which window line you want
continued, if there is more than one.  The second method is more
convenient to use.  It places the quote mark on the last blank
line that immediately follows a non-blank line.

You may continue placing " marks on as many lines as you have,
creating a multi-line display.

The debugger follows the " mark with the address of memory being
displayed, followed by the memory, according to the start of the
type specification of the line being continued.  The memory
display is aligned with the display of above line.

If you are creating a multi-line display, and your specification
is a long one, you may wish to start the display at the beginning
of the next line, rather than after the specification on the
first line.  This will often give you more room.  You do this by
terminating the format specification with a slash / instead of a
comma.  For example, to display many hex bytes at the array
BYTE_ARRAY, type 1b/byte_array<Enter> followed by five double
quote marks, when the memory display is empty.


Mixed Format Specification

Instead of having all your bytes or words on a line displayed in
the same format, you can mix your formats.  You do this by
providing more than one letter in your format specification.  The
debugger will display one memory unit for each letter-type you
specify.  The line will be filled out with the last type given.
For example, if you type 3nwb,01000<Enter>, you will get a
display on memory line 3 of the decimal byte at 01000, the hex
word at 01001, and an array of hex bytes starting at 01003.


Numbers in a Format Specification

You may precede any letter in a format specification with a
number up to 255. The effect is the same as if you had repeated
the letter the given number of times.  For example, if you type 1
to go to memory line 1, followed by 4w10tb,02000<Enter>, you will
get 4 hex words at 02000, 10 text characters at 02008, and an
array of hex bytes from 02012 filling out the rest of the line.

You may also end your format specification with a number up to
255.  This will cause the entire specification to be repeated the
given number of times. If there is room on the line for the full
number given, the display will stop there -- there will be no
repeating of the last type byte.  If there is not room on the
line for the full number of global iterations, the debugger will
stop at the end of the last iteration that would fit.  For
example, the specification b8 causes 8 hex bytes to be displayed,
and the remainder of the display line to be blank.  The
specification b3w9 will cause the debugger to try to output 9
records, each consisting of a hex byte followed by 3 hex words.
After putting out 2 such records, the debugger will see that
there is not room for a third full record, so it will stop.  This
stopping at the record boundary allows you to continue the
display, with correct alignment, on subsequent lines.


Spacing Between Memory Display Units

In general, the debugger provides a space between each unit (byte
or word) it displays.  There is an exception, however: the
debugger will not space between adjacent text characters (A,C, or
T specifications).

There are special specifiers G, J, and M, described in the
                                                              23

section below, that allow you to override the debugger's spacing
policies.


Special-Action Format Specifiers

In addition to the 9 letters already mentioned that specify data
types, there are 9 other letters, and 2 other characters, that
cause the debugger to perform special actions.  Following is a
complete description of all 20 non-digit characters that can
occur within a format specification:

=  causes a display, using the format of the letter following =,
   of the current memory pointer value, instead of the contents
   of the memory location.  If a letter does not follow the =,
   then W is used; i.e., the pointer is displayed as a 4-digit
   hex word.  Two uses for this feature come to mind:

   * If your address specification is symbolic, you can display
     the equivalent numeric address with =w, telling you exactly
     where the symbol is in memory.  Note that this display
     implicitly occurs at the beginning of continuation lines. If
     the format specification begins with =, then the implicit
     display is suppressed, because the same address is given
     explicitly by the L.

   * You can display the values of registers in a format other
     than hex.  For example, in the 8086 debugger you can display
     AX as a decimal number by specifying =d1,ax on one of the
     memory display lines.

@  causes the debugger to read the next byte it was going to
   display, and instead of displaying the byte, use it as a
   count, to repeat the next letter in the specification.  The
   debugger uses only the bottom 7 bits of the memory byte for
   the count.  For example, if the memory contains a length byte
   followed by that number of text characters, the text could be
   displayed by specifying @t (or @a or @c, depending on what you
   want the display to look like).  If the memory contains 05 41
   42 43 44 45, the @t would cause ABCDE to be displayed.

A  causes a display of a single ASCII byte, always using 2
   display bytes.  Bytes in the Ctrl-key range (00--01F) display
   as ^ followed by the corresponding letter; e.g. ^B for 02.  If
   the top bit is on (range 080--09F), $ is used instead of ^;
   e.g. $B for 082.  Displaying ASCII characters whose top bit is
   on have a prepended #; e.g., #1 for 0B1.  022 is "", 023 is
   "#, 024 is "$, 05E is "^, 07F is ^r (r stands for rubout), and
   0FF is $r.  All other characters are their normal selves
   preceded by a space.

   The A specification is used when you need guaranteed display
   length for proper alignment of continuation lines; and you do
   not want the potential loss of information provided by the
   single-byte T specification.

B  causes a display of a single byte as a 2-digit hexadecimal
   number.  Numbers less than hex 10 have a leading 0, so that
   the display is always 2 digits.

C  causes a display of a single ASCII character, just as the A
   specification, except that normal characters (not in the
   table) display as just one byte, without the preceding space.

D  causes the display of a 16-bit word as an unsigned positive
   decimal number. There will be no leading zeros in the display;
   so the length of the display depends on the size of the
   number.

F  causes the display of a floating point number, in one of the
   three formats recognized by the 8087.  You must have a
   floating point chip (8087 or 287) installed in your computer
   for this to work.  You specify which of the three formats you
   are reading by one of three letters immediately following the
   letter F:

   FD  specifies a 4-byte Doubleword (single precision) number
   FQ  specifies an 8-byte Quadword (double precision) number
   FT  specifies a Ten-byte number-- 8087 extended precision.

G  causes a gap between the adjacent display formats, of one
   space more than there would have been without the G.  For
   adjacent string bytes, this means a space where there would
   have been none.  For other data types, this means two spaces
   where there would have been one.

J  (join) causes two adjacent data types, that would have had a
   space between them, to have no space.

L  (line) causes the display of an entire text line, using the
                                                              24

   C-format for each character of the line.  The debugger does
   not display the terminating carriage return; nor does it
   display the following linefeed if there is one.  (If you want
   it to, specify LUC or LUUCC instead of L.)  If a carriage
   return is not found and the display line fills, then the
   L-specifier is cut off in mid-string.  Any continuation line
   will start up at the beginning of the format specification, at
   the mid-string place in memory.

M  (mark) causes a vertical-bars symbol to be displayed.  The
   symbol will replace a separating space that would have been
   output in the position.  If you want the space, you can
   provide G on either side (or both sides) of the M.

N  (number) causes the display of an 8-bit byte as an unsigned
   positive decimal number.  There will be no leading zeroes in
   the display; so the length of the display depends on the size
   of the number.

O  causes a display of a 16-bit word as a 6-digit octal number.
   Numbers less than octal 100000 have one or more leading
   zeroes, so that the display is always 6 digits.

Q  causes a display of a single byte as a 3-digit octal number.
   Numbers less than octal 100 have one or more leading zeroes,
   so that the display is always 3 digits.

S  causes the display of an entire null-terminated string, using
   the C-format for each character of the string.  The
   terminating null (hex 00) does not generate a display (if you
   want it to, specify SUC instead of S).  If a null is not found
   and the display line fills, then the S-specifier is cut off in
   mid-string.  Any continuation line would start up at the
   beginning of the format specification, at the mid-string place
   in memory.

T  causes the display of a single ASCII text byte, with a
   guaranteed display space of one character.  The character
   displayed is the same as the second character of the A-format.
   This means that you will not be able to tell the difference
   between normal, displaying ASCII characters, and their control
   and non-ASCII counterparts.  You gain a compact
   representation, but you also gain ambiguity.

U  (unskip) causes the memory display pointer to decrement by one
   byte.   No display is generated by this command.  This command
   is useful in several contexts:

   * displaying memory in more than one format.  For example, the
     specification 8b8u2g8a gives a hex-and-ASCII side-by-side
     display, similar to that provided by many memory dump
     programs.

   * displaying memory out of its sequence order.  To test your
     understanding of the special-action letters in a format
     specification, you should convince yourself that the
     specification xb2ujbx99/ gives the same display on the
     following " continuation line as the specification w/ does.

   * displaying the count byte consumed by the @ character.  For
     example, instead of @t, you could specify nu@t, which would
     display the string count as well as the string.  If memory
     were 05 41 42 43 44 45, this would be 5 ABCDE.

W  causes a display of a 16-bit word as a 4-digit hex number.
   Numbers less than hex 1000 have one or more leading zeroes, so
   that the display is always 4 digits.

X  causes the debugger to skip over the memory byte currently
   pointed to, without displaying it.  The memory pointer is thus
   incremented.

Z  is given immediately following another format letter.  It
   causes the display to fill out the line with displays of the
   given preceding format; but instead of starting with the given
   address, the debugger starts with a lower address, and
   displays memory up to but not including the given address.

   The most common usage of Z is to display the memory just
   output by a moving output pointer.  For example, in the 8086
   debugger, you could specify bz,es,di to display the hex bytes
   most recently output by the STOSB instruction.

   Note that Z makes sense only in a limited number of contexts.
   You will almost certainly want to use Z only as the second
   letter of a two-letter specification, as in the example above.
   I further recommend that you use a format letter that
   generates a fixed length display; i.e., B,W,Q,O,T, or C.  If
   you use a variable length display (N,D, or A), the debugger
                                                              25

   will be as pessimistic as possible about the number of display
   characters needed, so that the display will likely terminate
   before the end of the line.

   A continuation of a Z-line will produce the same output as the
   original line.  If you want to continue beyond the address
   given, repeat the specification without the Z.


The Data Memory Window

You may cause the switchable window in the upper right quadrant
of the screen to display 14 lines of memory, continuing from the
last of the lines you specified within the 6-line memory area. To
do this, you:

1. Type a format-and-address specification on one of the numbered
   memory lines, as previously described in this chapter.  For
   example, to display Bytes at location DS:0100, type 6b,ds,0100
   followed by the Enter key.

2. If you have already selected the memory window, you'll
   automatically have a continuation of the memory line you just
   specified, into the upper right quadrant of the screen.  If
   not, you may select the window by pressing either the Ctrl-N
   or Ctrl-P keys.

Once you have set up a 14-line window, you may page through
memory with the Ctrl-N (Next memory page) and Ctrl-P (Previous
memory page) keys, described in Chapter 4.

If, after having pressed Ctrl-N or Ctrl-P several times, you wish
to return to the first window continuing from the address you
specified, you may do so by typing the digit (1 to 6) of the last
specification line, followed immediately by the Esc key to
preserve the specification settings.  The memory window will be
reset to its continuation value.  For example, if your
specification was on line 6, you type 6 followed immediately by
the Esc key.

If you want your 14-line memory window to start at a certain
address instead of continuing from a 1-line display, you can
separate the format and the address with a slash instead of a
comma.  For example, if you want Words at location ES:0, type 6
followed by w/es,0 followed by the Enter key.
                                                              26


CHAPTER 7    FLOATING POINT DEBUGGING

If your machine has a floating-point processor, D86 gives you the
best facilities for debugging code for the processor (which I
generically refer to as "the 87").

The display of the 87's state can be obtained by pressing the
Ctrl-F key.  If you don't have an 87 in your system, you won't
get the display.

You can also display floating point numbers displayed in 86
memory, by using the FD, FQ, and FT specifiers described in
Chapter 6.

In the displays of floating point numbers, both on the 87 stack
and in 86 memory, I've taken great care to provide a display that
is both readable and accurate.  I rejected the algorithms for
display found in the popular reference books on the subject,
because they failed for several classes of extreme values.


The Floating Point Display Window

The floating point display you get with Ctrl-F contains the
following components:

1. The top 8 lines contain the contents of each floating point
   register.  The registers are displayed as a stack, with ST(0)
   on top, numbered with "0:".  The format of the display depends
   on whether the number is a plain, normal number, or whether it
   is one of the exotic, non-normal types the 87 supports.  I'll
   briefly describe the exotic types at the end of this chapter.
   The possible displays are:

   ----       (four hyphens), denoting a stack slot tagged empty.

   nnn        a decimal number, displayed in scientific notation
              if necessary.

   Infinity   for an overflowed result.

   NaN        for Not a Number, followed by the hex codes of the
              significand field of the NaN

   Den        for denormal, followed by the number of bits of
              precision lost, followed by the value of the
              number.

   Unn        for unnormal, followed by the number of bits of
              precision lost, followed by the value of the
              number.

   Pseudo 0   for a pseudo zero, followed by the contents of the
              exponent field.

2. English-language displays for the infinity, precision, and
   rounding mode settings for the chip.

3. The value of the instruction pointer for the instruction that
   caused the last floating-point exception.  If all exceptions
   are masked this doesn't change.

4. The address of the memory operand for the instruction that
   caused the last floating-point exception.  If all exceptions
   are masked this doesn't change either.

5. The value of the Tag register, for registers 7 through 0.
   These register numbers are NOT the same as the stack element
   numbers -- they are rotated by the value of ST, given on the
   next line.  The possible values for the Tag register fields
   are:

   f   for finite non-zero number
   z   for zero
   i   for infinite number
   -   for empty slot

6. The value of the stack pointer ST.  The tag-register number
   for ST(i) is ST plus i.

7. A display of which 87 exceptions are masked; i.e., will not
   cause interrupts.  If the exception is masked, its letter is
   displayed.  If it is not masked (interrupt will occur), a
   blank is displayed.  The letters are:

   p   for precision exception
   u   for underflow exception
   o   for overflow exception
   z   for zero-divide exception
   d   for denormal exception
   i   for invalid operation exception

8. A display of which masked exceptions have occurred since the
   last time the status bits were cleared.  The exceptions have
   the same letters as the masked display.

9. A display of the 87 Condition Flags C3 through C0.  A
   displaying character is shown if the flag is set; a blank is
   shown if the flag is cleared.  The characters are:

   z  for C3  (corresponds to the Zero flag)
   u  for C2  (set if a result is "unordered")
   .  for C1
   c  for C0  (corresponds to the Carry flag)

10. Another display of C3 through C0, this time showing the
   results of an FXAM instruction.  This display is always
                                                              27

   present, even when FXAM is not the last flag-setting
   instruction executed (in which case the display is
   meaningless).


Exotic Flavors of Floating Point Numbers

Some of the types of numbers possible in the floating point
register display may seem a little strange to you if you haven't
had much experience with the 87.  It's a bit beyond the scope of
this manual to go into detail about them -- you should consult a
book on the theory of floating-point processing, for a detailed
discussion.  But here are brief descriptions to give you a bit of
an idea of what's going on:

NaN (Not-a-Number) values are used to represent results that are
totally different than any floating-point number that could be
provided.  A specific NaN (with hex value C000 0000 0000 0000) is
produced by the 87 whenever it can't cope with something, and the
Invalid Operation exception is masked.  Other NaN values might be
loaded by a program from 86 memory, to be interpreted in any way
the program chooses.

For the rest of this discussion, let's introduce a little
terminology.  Floating point numbers use a format that follows
the same principle as scientific notation.  In scientific
notation, one part of the number gives the significant digits of
the number, always "normalized" to fall between 1 and 10. Another
part of the number gives the magnitude of the number: the power
of ten that you multiply the first part by, to get the true
value.  For example, 2.34 * 10**2 is a normal, scientific
notation for 234.  (It can be written in A86 as 2.34E2).  2.34 *
10**-2 is a normal scientific notation for 0.0234.  Note that
0.234 * 10**-1 is a non-normal representation for the same
number: we have increased the size of the exponent from -2 to -1,
but the significant part is less than 1 instead of being between
1 and 10.

In the 87 formats, everything is binary, with bits instead of
digits.  There is a "significand" field, normalized whenever
possible so that the most significant bit is 1 (the value is
between 1 and 2).  There is the "exponent" field, giving the
(positive or negative) power of two that you multiply the
significand by, to get the true value.

Denormals are produced when the result of an operation is non-
zero, but is so tiny that its exponent is a negative number too
small to be represented in the 15-bit exponent field of an 87
register.  There is a trick called "gradual underflow" that makes
the best of the situation: the smallest possible exponent is
given, together with leading zeroes in the significand to signal
a further reduction in the exponent.  Each leading zero means
there is one less bit with which to represent the significand.

You can see denormals in action by typing Ctrl-F to get the
floating-point display, then typing the following commands to be
executed immediately:

     FINIT
     FLD 10.0
     FLD 1.E-4931
     FDIV 1

The result of the division is a denormal because 10 ** -4932 has
a power-of-two exponent too small to be represented in the 15-bit
exponent field of the 87 register.  The display indicates that 2
bits of precision have been lost -- two leading zeroes have been
forced into the significand field of the number.

Now press the F3 key to divide the number by another 10.  Now 5
bits of precision have been lost.  If you keep pressing the F3
key, you get more and more bits of precision lost.  The loss in
accuracy shows up in the number displayed.  Eventually, all bits
are lost, and the number collapses to zero.

What happens when we multiply a denormal number by 10, instead of
dividing it by 10?  The number becomes big enough to no longer
require the denormalization; but there's no way to recover the
bits of precision that have been lost.  To signal that bits have
been lost, the 87 retains the leading zeroes in the significand.
                                                              28

Numbers containing such zeroes without the minimum exponent are
called "unnormals".

A certain kind of unnormal is a "pseudo-zero", obtained when all
the bits of precision are lost.  This can happen when you
multiply two unnormals.  The number of leading zero bits
(precision bits lost) of the answer is the sum of the bits lost
of the operands.  If the total is 64 bits or more, all precision
is lost -- the significand is zero.  But the exponent field is
nonzero, which brands the number as strange -- a true zero has
zeroes in the entire number, including the exponent field.
                                                              29


CHAPTER 8   COMMONLY ASKED QUESTIONS


Setting Registers

Q: Why isn't there a debugger command to modify register
settings?

A: You can do so with an immediate assembly language command. For
   example, to set the AX register to 100 type MOV AX,100 . You
   can now also set segment registers this way: MOV DS,0 REMEMBER
   that if there isn't a leading zero, all constants fed to D86
   are assumed to be decimal.  If you want hex constants, supply
   a leading zero.

Q: How do you reset the CS register?  MOV CS,value doesn't work.

A: You issue a far JMP instruction to be executed immediately.
   For example, to set CS to 0 and IP to 400 hex, type JMP 0:0400


Modifying Memory

Q: Why aren't there commands for changing memory to different hex
   values, or for filling memory with a given value?

A: You can do this very effectively with D86's patch memory mode.
   Just issue an immediate JMP to the location you want modified,
   press the F7 key to enter patch-memory mode, and then issue
   any A86 directive to initialize memory: DB for bytes, DW for
   words, DD for doublewords, etc.  Remember, you have the full
   power of the A86 language at your disposal.  You can provide
   lists of values on a single line:

   DW 0100,0101,MY_SYMBOL

   You can make ASCII initializations with strings on DB lines:

   DB 'This is a string',0D,0A,0

   You can use the DUP construct to fill memory with a given
   value or sequence of values:

   DB 100 DUP 0, 10 DUP (1,2,3)


Debugging ROM

Q: I tried stepping into a ROM BIOS routine.  It worked for a
   while, but when I got to a certain instruction and stepped,
   the computer crashed.  What's wrong?

A: My official policy on stepping into ROM is, "all bets are
   off".  D86 does better than many debuggers at stepping into
   ROM, but there are still some fairly insurmountable problems.
   First, D86 itself calls the BIOS.  Not all BIOS routines are
   reentrant; you could get unfortunate interactions between the
   call being stepped and calls made by D86 while you are
   stepping.  Second, ROM cannot be modified and hence traps
   cannot be set within ROM.  D86 doesn't try to detect failed
   trap-setting, so the program may be set loose in situations
   where D86 thinks (and you think) it will retain control.

   This will always happen if you try to step a whole CALL in
   ROM.  It will also happen if you try to use the F1 key on an
   instruction that loads a segment register.  For arcane
   reasons, the single-stepping feature built into the 8088
   doesn't work on such instructions, so D86 must single step
   them with a trap.  Thus, F1 on a segment-loading instruction
   in ROM will set the program loose.
                                                              30


CHAPTER 9    RELEASE HISTORY AND FUTURE PLANS


Release History of D86

All releases include bug fixes.

V2.15  August 1986.  Initial public release of the MSDOS version
       of D86. The last previous version ran under the Xenix
       operating system on the Altos series of computers. I
       improved the invocation syntax, incorporated IBM function
       keys into the interface, and added on-line help.

V2.16  August 1986.  Added the ability to make forward references
       in patch-memory mode.

V2.18  November 1986.  Added the "O" command, to trap INT 33
       calls.

V2.22  April 1987.  Release in conjunction with A86 V3.00.  Added
       support for new 286 and NEC-specific instructions.  Added
       "F" command, and Shift-F7 commands.  Added the floating
       point window.

V3.09  August 1987.  Major upgrade: first product-quality
       release.  Added support for EXE files, some support for
       BAT files, second disassembly window, extended memory
       display window, status window, floating point memory
       display types, backwards paging and sensible Up-Arrow, W
       command to write program and symbols to disk, enhanced
       Home key, Ctrl-T set top-of-stack key, and Ctrl-E
       go-to-end key.

V3.10  September 1987.   Trap INT 020 and INT 027.

V3.15  May 1988.  Added data breakpoint for 386-based machines,
       available to registered users only.

V3.18  July 1988.  Added MAPD86 tool for registered users only.

V3.20  July 1989.  Added F9 key.

V3.21  August 1989.  Added Ctrl-X key, and changed F1 not to step
       into interrupts.

V3.22  January 1990.  Added support for the IIT-2C87 and 80387
       coprocessors.

V3.70  January 1994.  Test release in conjunction with A86 V3.70
       test release.

V4.00  December 1994.  Added the keystroke-script-saving
       facility, with the K command, the S system-functions
       command, the Undo command, default key scripts, and
       Alt-letter key scripts. Changed F2 to single-step loops
       and jumps, making the F5 key the "trap next instruction"
       that F2 had been.

V4.01  March 1995.

V4.02  September 1995.

V4.03 January 1996.


Future Plans

I'd like to thank all of you who have supported A86 and D86 so
far with your registrations.  Your support has allowed me to
spend the past thirteen-plus
 years working exclusively on my shareware products.

D86 improvements have been slower to implement than I hoped.  I
still wish to provide the ability to save and switch to/from the
program's full screen, and to interrupt a running program from
the keyboard.  I hope I can get to those eventually.  I will also
be exploring programming for the Windows environment (my ZIPKEY
customers are screaming for a Windows version!), and may bring
out tools and/or new A386/D386 features associated with that.
                                                              31

INDEX

386 breakpoints, 16
87 debugging, 26
A  memory specifier, 23
adding symbols, 12
address, my, 3
addresses, displaying, 23
advantages of D86, 3
Alt-F10 key, 13
ALT-letter commands, 18
ALTx.D8K file, 18
arrays, displaying, 21
ASCII byte, 2-character display, 23
at-sign format specifier, 23
B  memory specifier, 23
B breakpoint command, 16
BAT files and D86, 9
benefits of registration, 4
BIOS output, forcing, 10
BIOS switching, D86, 10
blanking memory display lines, 21
breakpoints on data references D, 16
breakpoints on system calls with O, 19
breakpoints, clearing B, 16
breakpoints, displaying B, 16
breakpoints, fixed B, 16
breakpoints, transient G, 17
British contact, 3
bugs, reporting, 5
C  memory specifier, 23
CALL commands, immediate, 11
Carry flag, demo, 7
color monitor, 10
COM files, debugging, 9
commands, classes of D86, 11
commonly asked questions, 29
Compuserve section, 5
condition flags, floating, 26
conditional destination trap F4, 15
contacting me, 5
continuation of memory display, 22
control keys, display, 13
copying files within D86, 19
count byte, displaying, 24
crashing while debugging ROM, 29
credit cards, 3
CS register, setting, 29
CS trickiness and D86, 11
CS, strange values, 18
Ctrl-D key, 14
Ctrl-E key, 14
Ctrl-F key, 13
Ctrl-I key, 13
Ctrl-K with K command, 18
Ctrl-M key, 15
Ctrl-M with K command, 18
Ctrl-N key, 13
Ctrl-P key, 13
                                                              32

Ctrl-Q key, 13
Ctrl-R key, 15
Ctrl-S key, 13
Ctrl-T key, 15
Ctrl-U key, 14
D  memory specifier, 23
D86 environment variable, 10
D86.D8K file, 18
D86_BUFFER, 11
D8K script files, 18
data, entering into memory, 12
debugger commands, 16
DEC Rainbow BIOS switch, 10
decimal byte N memory specifier, 24
decimal word D memory specifier, 23
decrementing IP, 14
deleting files within D86, 19
demonstration, D86, 6
Den denormal display, 26
denormals, 27
denormals, example, 27
DI, displaying before, Z, 24
disassembly page, second, 13
disassembly to a file, 19
disassembly, paging, 14
disassembly, synchronizing, 14
display control keys, 13
display of multi-format memory, 24
displaying before a memory address, Z, 24
DOS call breakpoints O, 19
double quotes for memory continuation, 22
Down-Arrow key, 14
e-mail address, 5
electronic mail, 5
End of program, jump to, 14
English contact, 3
entering symbols, 12
environment variable, D86, 10
equals sign format specifier, 23
erasing memory display lines, 21
ESC key to preserve memory display, 22
ET-100 BIOS switch, 10
exception pointer display, 26
exceptions, 87 display, 26
EXE files, debugging, 9
EXE files, recognizing, 9
execution keys, 14
exit breakpoint, permanent, 19
exiting the debugger, 19
exotic flavors of floating-point numbers, 27
exponent field, 27
F  memory specifiers, 23
F command, 17
F1 key, 14
F10 key, 13
F2 key, 15
F3 key, 15
F4 key, 15
F5 key, 15
                                                              33

F6 key, 15
F7 key in D86, 12
F9 key, 15
FD memory specifier, 23
file,  D86 program, 9
file, symbols, and D86, 9
files, copying and deleting, 19
finding strings in memory F, 17
finding the D86 program file, 9
fixed breakpoints, setting B, 16
flags display, D86, 11
flags, D86 demo, 6
floating point memory display, 23
floating window key, 13
floating-point debugging, 26
flushing keystrokes, 18
format specifiers, special action, 23
formats, mixed memory, 22
forward references, patch mode, 12
FQ memory specifier, 23
frozen at INT 021 due to exit function, 19
FT memory specifier, 23
future plans, D86, 30
FXAM setting display, 26
G  memory specifier, 23
G command, 17
gap memory specifier, 23
gradual underflow, 27
Great Britain contact, 3
hardware compatibility, D86, 10
help mode, toggling, 13
help-mode key, 13
here, go until, F9 key, 15
hex byte B memory specifier, 23
hex word W memory specifier, 24
HEXOUT.8, 6
history of D86, 30
Home key to restore IP, 14
Home key, 14
how to contact me, 5
IBM-PC BIOS switch, 10
immediate assembly language commands, 11
immediate-execute, demo, 6
incentives to register, 4
incrementing IP, 14
infinity display, 26
infinity mode display, 26
instruction pointer positioning, 14
Internet mail address, 5
invocation switches, D86, 10
invoking D86, 9
IP down and up keys, 14
IP, positioning, 14
J  memory specifier, 23
J command, 18
JMP commands, immediate, 11
joining memory displays, 23
jumping within a strange CS, 18
K command, 18
                                                              34

keys, display control, 13
keystroke scripts, 18
L  memory specifier, 23
L command, 19
last command, F3 repeat, 15
last execution point, return to, 14
legal terms, 3
length byte, displaying, 24
length-byte specifier, 23
letter commands, D86, 16
letters, lower-case display, D86, 11
line memory display, 23
loops, breaking past, 15
M  memory specifier, 24
machine switches, D86, 10
MAPD86 tool, 9
mark location for F key, 15
mark location for K key, 15
mark memory display, 24
marked location, use of with F, 17
masked exceptions display, 26
memory accesses, trapping on, 16
memory display continuation, 22
memory display, 21
memory display, demo, 7
memory display, floating point, 23
memory display, preserving, 22
memory displays, erasing, 21
memory formats, simple, 21
memory modifying examples, 29
memory window display key, 13
memory window, reset after paging, 25
memory, altering, 12
mixed memory formats, 22
MODE command, 10
mode displays, floating-point, 26
monochrome monitor, 10
MOV to segment registers in ROM, 29
MS-DOS function breakpoints O, 19
multi-format side-by-side display, 24
N  memory specifier, 24
NaNs, 27
next instruction, trapping, 15
next memory page key, 13
NOPs in D86 display, 9
Not-a-Number, 27
null-terminated string display, 24
NULL.D8K file, 18
numbered memory windows, D86, 11
numbers in a memory format, 22
O  memory specifier, 24
O command, 19
octal byte Q memory specifier, 24
octal word O memory specifier, 24
online support, 5
operands to debugger commands, 16
operating requirements, D86, 9
output strings, displaying via Z, 24
overview of D86, 4
                                                              35

paging the disassembly, 14
patch memory, demo, 8
patching memory, 11
PATH and keystroke scripts, 19
Path variable and programs, 9
PgDn key, 14
PgUp key, 14
phone number, my, 3
plans, D86, 30
playing back keystrokes, 19
precision mode display, 26
precision, loss of, 27
previous memory page key, 13
prices, 3
procedure-stepping F2 key, 15
program file, D86 finding, 9
program file, status, 10
program start, go to, 14
program, saving patched, 20
Pseudo zero display, 26
pseudo-zeroes, 28
PSP for immediate-buffer, 11
Q  memory specifier, 24
Q command, 19
questions, commonly asked, 29
quitting the debugging session, 19
quotes, double, for memory continuation, 22
redo an undone keystroke, Ctrl-R, 15
registers, floating-point, 26
registers, non-hex display of, 23
registers, setting, 29
registration benefit D command, 16
registration benefits, 4
release history, D86, 30
repeat count, memory display, 22
repeat last command F3 key, 15
repeat-count specifier, 23
requirements, D86, 9
reset debugger session, 19
RET commands, immediate, 11
retracting keystrokes, 20
return, F6 trap on, 15
reverse engineering, 12
revision history, D86, 30
ROM code, CS trickiness, 11
ROM debugging, 29
rounding mode display, 26
S  memory specifier, 24
S command, 19
Sanyo 550 BIOS switch, 10
saving keystrokes, 18
saving symbols and program, 20
scientific notation, 58, 27
screen display, D86, 10
searching memory F, 17
second disassembly key, 13
segments in memory display pointers, 21
Shift-F7 key, 15
side-by-side display, 24
                                                              36

sign-on display, reaching, 13
significand, 27
single-line memory windows, 21
single-stepping keys, 14
single-stepping, demo, 7
Sirius/Victor BIOS switch, 10
skipping backwards in memory, U, 24
skipping forwards in memory display, X, 24
spacing a memory display, 22
special action control keys, 15
special action format specifiers, 23
stack pointer, floating-point display, 26
stack, setting top of with Ctrl-T, 15
start of program, go to, 14
starting your program with G, 17
status window key, 13
stepping keys, 14
STOSB memory display, Z, 24
strings, null-terminated, display, 24
structures, displaying, 22
subroutine-stepping F2 key, 15
switches, D86, 9
SYM extension and D86, 9
symbols file and D86, 9
symbols, adding, 12
symbols, saving, 20
synchronizing disassembly, 14
system calls, 19
system requirements, D86, 9
T  memory specifier, 24
TAB key, 13
tag register display, 26
Tandy 2000 BIOS switch, 10
telephone number, my, 3
terms, legal, 3
Texas Instruments PC BIOS switch, 10
text, 1- or 2-byte C display, 23
text, 1-byte T display, 24
text, 2-character A display, 23
tiny numbers, 27
toggling display windows, 13
top of stack, setting with Ctrl-T, 15
transient breakpoints G, 17
trap at present location F9 key, 15
trap next instruction key F5, 15
trapping function keys, 15
trapping on memory accesses, 16
two-screen debugging, 10
U  memory specifier, 24
U command, 20
underflow, gradual, 27
undoing a debugger command, 20
Unn unnormal display, 26
unnormals, 27
unskipping memory display, 24
Up-Arrow key, 14
V switch, D86, 10
version history, D86, 30
vertical bars display, 24
                                                              37

W  memory specifier, 24
W command, 20
Wang-PC BIOS switch, 10
Wettstein, Greg, 5
window, 14-line memory, 25
window, memory, reset after paging, 25
Windows plans, 30
windows, memory display, 21
writing program and symbols files, 20
X  memory specifier, 24
Z  memory specifier, 24
Zenith BIOS switch, 10
